
By American Wood Council
ISBN-10: 0962598534
ISBN-13: 9780962598531
ISBN-10: 0962598585
ISBN-13: 9780962598586
Wind and Seismic layout advisor, published to be used with 2005 NDS wooden layout package deal.
Read or Download ASD/LRFD Wind & Seismic, Special Design Provisions For Wind And Seismic, With Commentary PDF
Similar civil & environmental books
Get Cold-Formed Steel Design, 4th Edition PDF
The definitive textual content within the box, completely up to date and expandedHailed by means of pros world wide because the definitive textual content at the topic, Cold-Formed metal layout is an quintessential source for all who layout for and paintings with cold-formed metal. No different booklet presents such exhaustive assurance of either the idea and perform of cold-formed metal development.
Read e-book online IntelliBau 2: Das intelligente Bauteil im integrierten PDF
Im Lebenszyklus von Bauobjekten verursachen Medienbrüche bei der Informationsweitergabe regelmäßig Datenverluste. Mit dem Modell des „Intelligenten Bauteils“ wurde eine Lösung entwickelt, um einen durchgängigen Datenfluss ohne Medienbrüche mit Hilfe der RFID-Technologie zu gewährleisten. Im vorliegenden Abschlussbericht zum Forschungsvorhaben „IntelliBau2“ werden die Nutzungsvorteile der RFID-Technologie in der Fertigteilproduktion dargestellt.
New PDF release: Design of Concrete Structures Using High-Strength Steel
This file presents an review of present "AASHTO LRFD Bridge layout requirements" appropriate to using high-strength reinforcing metal and different grades of reinforcing metal having no discernible yield plateau. The document additionally contains suggested language to the "AASHTO LRFD Bridge layout requisites" that would let using high-strength reinforcing metal with designated yield strengths no longer more than a hundred ksi.
Download e-book for iPad: Volunteer training drills : a year of weekly drills by Howard Chatterton
Education is ready studying new abilities and certifying the power to accomplish them to a given usual. part 1 starts with a one-year define for education officials. part 2 follows with a desk of listings for every define given within the e-book, indicating even if the drill is inside of or open air and the instruction time wanted for it.
- Seismology
- Rapid Excavation and Tunneling Conference Proceedings 2009
- Fireworks: The Art, Science, and Technique
- Introduction to soil mechanics
- Geotechnical Earthquake Engineering
Additional resources for ASD/LRFD Wind & Seismic, Special Design Provisions For Wind And Seismic, With Commentary
Sample text
Maximum nail spacing of 6" on center along intermediate framing members. 3. 2" nominal or wider framing at adjoining panel edges. 4. Maximum stud spacing of 16" on center. 5. Minimum length of galvanized roofing nails is 1-½" for ½" thick sheathing and 1-¾" for 25/32" thick sheathing. 6. 1 or ASTM C 208. 4 Gypsum Wallboard, Gypsum Veneer Base, Water-Resistant Backing Board, Gypsum Sheathing, Gypsum Lath and Plaster, or Portland Cement Plaster Shear Walls: Shear walls sheathed with gypsum wallboard, gypsum veneer base, water-resistant backing board, gypsum sheathing, gypsum lath and plaster, or portland cement plaster shall be permitted to be used to resist wind forces and seismic forces in Seismic Design Categories A through D.
As a result, diaphragm dimension and diaphragm aspect ratio limitations are provided for different building configurations. The test for torsional irregularity is consistent with general seismic design requirements (5). 1 Open Front Structures: A structure with shear walls on three sides only (open front) is one category of structure that requires transfer of forces through rotation. Shear force is transferred to shear wall(s) parallel to the applied force and moment due to eccentric loading is transferred into perpendicular walls.
1. 3 to determine ASD allowable unit shear capacity and LRFD factored unit resistance. 6. 3 for fiberboard shear walls. 2. Shears are permitted to be increased to values shown for 15/32 inch sheathing with same nailing provided (a) studs are spaced a maximum of 16 inches on center, or (b) panels are applied with long dimension across studs. 3. 5 – G)], where G = Specific Gravity of the framing lumber from the NDS. The Specific Gravity Adjustment Factor shall not be greater than 1. 4. Apparent shear stiffness values, Ga, are based on nail slip in framing with moisture content less than or equal to 19% at time of fabrication and panel stiffness values for shear walls constructed with OSB panels.
ASD/LRFD Wind & Seismic, Special Design Provisions For Wind And Seismic, With Commentary by American Wood Council
by Christopher
4.5